                                     Water to water cooler/heat exchanger

Use: boiler room

The cooler is using for capture of hot water to examinate.The water is cooling bringing it up to environment temperature. Cooling takes place through a cold water flow. 

The water to cool is cooled by the flow of cold water.

Used to reduce the temperature of hot water before analysing. 

Models: "manual" model, destined to hot water sample for analysis with a  testkit,” and “automatic” destined to cool the water before water analyzer. 

4 models available:

 Manual cooler

(smart model)

Manual cooler

(big model)

  

 Analyzer cooler

(smart model)

Analyzer coooler

(big model)

 

 Tecnical data

 
Manual

Manual Big

Automatic

Automatic Big

Code. Num
200037
200042
200030
200031

Max pressure of water to cool

16 bar
16 bar
16 bar
16 bar

Max pressure of cooling water

8 bar
8 bar
8 bar
8 bar

Hot water temperature

0 – 80 °C
0 – 120 °C
0 – 80°C
0 – 120°C
Dimension
413x 335 mm
598 x 335 mm
375 x 128 mm
546x 128 mm

Hydraulic link

Cold water input
Cold water output
Water to be cooled
Outlet water cooled
 
 
8 mm
½”
8 mm
8 mm
 
 
½”
½”
8 mm
8 mm
 
 
8 mm
8 mm
8 mm
8 mm
 
 
½”
½”
8 mm
8 mm

Lengh of cooling spiral

     2,6 meters
      5,1meters
     2,6meters
     5,1meters
Weight          3,3 kg                 4,0 kg              1,7 kg                     2,3 kg
Materials

steel titanium AISI316Ti4,EN 1.4571 (mounting bracket: AISI316L EN 1.4404)

Temperature Lowering 

 

< 40°C (with cooling water< 25°C and a water flow to analyze 

approximate  12 ltr/h)

Certification                                              PED 97/23/CE
Fluid classification                                      Class 2 - not dangerous fluids
Equipment classification (according to PED 97/23/CE)                                                       Class A

Destination use:

The cooler is destined to cool the boiler water  to low the temperature before analyzing. 

The cooler must be used only when it is in regular conditions. Possible dafaults must be eliminate completly.

Unright use: No use the cooler as a boiler  to warm water, neither in a open circuit, or in a closed circuit.

No use copper pipes.
 
Using limits:
 
The water must note the followings parameters:
 
Parameter
Unit
Max value

Free chlorine *

mg/l
0,2
Steel **
mg/l
0,2

Mangle     **

mg/l
0,05

Silicate     ***

mg/l
25
Chlorate
Mg/l
0
Value pH
-
4-8
 
 
 
 
* Free chlorine/chlorine dioxide/ozone: damage  cooler inner surface.
** Steel/mangle: It can be melted or unmelted.  If unmelted, filter it to eliminate  the overhung substances.  If melted, oxidate the steel/mangle with a filtering plant or using an antiscaling specific  proportioning. The scales on the inner surface are generally eliminated with a chemical productions washing. 
*** Silicate, can scale the inner surface.
**** Chlorate can damage the inner surface. 
 
 
Further alterations are reserved in the interests of continuous tecnical improvements.            